Abstract

Power converters operating in boundary conduction mode (BCM) can benefit from an efficiency increase compared to continuous conduction mode (CCM) based on the soft-switching transitions at turn- on and/or turn- off . However, for a given average inductor current, the RMS current in BCM converters becomes larger than in CCM converters, leading to an increase in conduction losses. Interleaving smaller BCM power converters overcome this drawback by reducing the total ripple current amplitude at the expense of an increase in complexity and in magnetic parts count. Nevertheless, as the magnetic devices are among the largest components in power converters, it is convenient to find the design conditions under which BCM or CCM could yield the smaller net volume. This paper proposes a method to estimate the volume ratio for magnetic parts, between single-phase CCM and multiple interleaved BCM power converters as a function of the number of phases, inductor loss, and switching frequency. The results obtained can be applied to boost, forward, and flyback dc-to-dc topologies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.