Abstract

This article presents methods and results of interlaboratory comparison in the electromagnetic field (EMF) survey measurements performed by Electromagnetic Environment Protection Laboratory. Based on the results, the author analyzed factors affecting the precision of EMF measurements, in particular—difficult to estimate—the “human factor”. In practice, the human factor has never been taken into account in the EMF measurements accuracy estimations budget, and the author estimate the importance of this factor that may include even up to half of the total uncertainty of measurements. Taking into account all factors depredating the accuracy of measurements, the uncertainty of the survey EMF measurements was estimated at the level of 2–4 dB.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.