Abstract

This study evaluated and compared the sealer thickness and interfacial adaptation of bioceramic sealers (Sankin Apatite III, MTA Fillapex(®), EndoSequence(®) BC) to root dentin against AH Plus(®) sealer. Sixty extracted single-root premolars were prepared and equally divided into four groups. Sealers were labeled with 0.1% Rhodamine B fluorescent dye. Roots were dissected along the transverse plane at 1 mm (apical), 3 mm (middle), and 6 mm (coronal) levels. Sealer-to-whole canal area ratio was evaluated. Percentage of gap-containing region to canal circumference was calculated using a confocal laser microscope. Sealer thickness was significantly higher at apical and middle levels than at coronal level. EndoSequence BC had the significantly highest thickness compared with MTA Fillapex and AH Plus. The coronal level had significantly less interfacial gaps compared with apical and middle levels. Bioceramic sealers showed more gaps compared with AH Plus, with no significant differences among them.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.