Abstract

Prevention of industrial machineries against internal and external faults is mandatory for uninterrupted operation. Identifying the exact faults or anomalies in the system and predicting the machine’s health continuously is an essential preventive measure. To realize the protection system, pre-analysis of various faults under different load conditions is mandatory and hence, paper analysis a critical fault “Inter turn fault” in the wound rotor induction machine (WRIM). Inter turn fault is developed experimentally in 2.2 kW WRIM with 20 percent of internal windings shorted under different load conditions (0 to 1 per unit load). Obtained results are analysed for various electrical and mechanical parameters, and the faulty effects are revealed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.