Abstract

An inter-laboratory study involving 24 laboratories was conducted to validate the modified analytical method for the migration solution of heptane for the determination of bisphenol A migrating from polycarbonate food processing materials. In this study, two concentrations of samples were blindly coded. Each laboratory determined the analyte (bisphenol A, phenol and p-tert-butylphenol) concentration in each sample according to the established protocol. The obtained values were analyzed statistically using internationally accepted guidelines. Horwitz ratios were calculated based on the reproducibility relative standard deviation (RSDR), which was estimated from the inter-laboratory study, and predicted RSDR, which was calculated using the Horwitz/Thompson equation. Horwitz ratios of the two samples ranged from 0.15 to 0.37 for the three compounds, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results showed that this modified analytical method shows good performance as an analytical method for the migration solution of heptane.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.