Abstract

We present a novel T-type half-open resonant photoacoustic (PA) cell for trace gas detection. The T-type PA cell has just one buffer volume, and a fiber-optic acoustic sensor is placed at one end of the resonator. Compared with the conventional H-type PA cell, the first-order resonant frequency of the T-type PA cell is reduced by half and the PA signal is enhanced with the same resonator. The T-type resonant PA cell was used in acetylene (C2H2) gas detection system based on PA spectroscopy. Experimental results show that the minimum detectable limit of C2H2 is calculated to be 0.70 parts per billion (ppb), which is lower than the traditional H-type PA cell.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.