Abstract

This paper presents a wide area control (WAC) method to coordinate the local controllers of generators and renewable energy sources (RESs), for robust power oscillation damping. The WAC signals are synthesized by a two-level hierarchical controller, which utilizes wide area measurements from all the installed synchronous generators and RESs for maximizing the performance of their corresponding local controllers. In the resulting WAC scheme, the generators are “aware” of the RES oscillations and vice versa, the RESs are “aware” of the generator oscillations. Further, the WAC signals intended for the RESs are adjusted in order to require only slight modifications on the RES local controllers. This study illustrates that the correct coordination of generators and RESs, through the WAC, improves the damping performance of the entire system even under high penetration of renewables. The performance of the proposed scheme has been tested and validated in the IEEE 9-bus and 39-bus test systems.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.