Abstract

The recent steep decline in the cost of PV panels and wind turbines provides an opportunity to utilise Hybrid Renewable Energy Systems (HRES) to fulfil thermal loads as well as the electrical demand. Two coupled system architectures are proposed and studied along with the base case of uncoupled architecture for comparison. The coupled systems include wind turbines, PV panels, battery bank, diesel generators (DG) or diesel-based Combined Heat and Power unit (CHP), boiler and thermal storage tank. Adopting a full factorial design of the experiment approach for each architecture, the optimum system is determined for a variety of combinations of the major influencing factors, namely, renewable resource intensity, thermal-to-electrical demand ratio and price of diesel fuel. Statistical analysis is conducted to investigate the effects of each factor on the cost of the system. The optimisation and statistical analysis show that, based on current prevailing components prices, an integrated system, which utilises excess electricity for fulfilling thermal loads, is cheaper than the base case with or without CHP unit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.