SummaryAutomated seizure detection in long-term video-EEG recordings is far from being integrated into common clinical practice. Here, we leverage classical and state-of-the-art complexity measures to robustly and automatically detect seizures from scalp recordings. Brain activity is scored through eight features, encompassing traditional time domain and novel measures of recurrence. A binary classification algorithm tailored to treat unbalanced dataset is used to determine whether a time window is ictal or non-ictal from its features. The application of the algorithm on a cohort of ten adult patients with focal refractory epilepsy indicates sensitivity, specificity, and accuracy of 90%, along with a true alarm rate of 95% and less than four false alarms per day. The proposed approach emphasizes ictal patterns against noisy background without the need of data preprocessing. Finally, we benchmark our approach against previous studies on two publicly available datasets, demonstrating the good performance of our algorithm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.