Abstract

The applicability of bremsstrahlung counting to in-situ measurements of high level tritiated water has been examined. A specially designed metallic vial fitted with a gold-coated beryllium window was prepared for the present examinations. Only tritiated water of a given amount was put into the vial. The volume dependence of the X-ray intensity showed that 5 cm3 of tritiated water is sufficient for measurements. It was found that the spectrum of X-rays induced by β-rays consisted of only bremsstrahlung. The bremsstrahlung spectrum could be reproduced quite well by computational simulation. A good linear relation between the X-ray intensity and tritium concentration was obtained in the concentration range of 4 × 10-3-40 MBq cm-3. Furthermore, effect of nickel added as a model impurity to tritiated water was examined, and it was found that the tritium concentration can be evaluated from the X-ray intensity without any correction in the presence of impurity below 200 ppm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.