Abstract

This study explores the use of the Kinect device for measuring Three-Dimensional (3D) Digital Elevation Models (DEMs) of wall-jet scour holes and its benefits and limitations. The Kinect device can accurately measure wall-jet scour holes in dry conditions with an accuracy of ±0.05 cm, but significant errors occur in the presence of water due to water surface refraction. A code based on Snell’s law was developed to correct these errors, resulting in good agreement with point gauge measurements with an accuracy of ±0.12 cm. The method is not recommended for tail-water depth ratios smaller than three and densimetric Froude numbers larger than 7.75 due to water surface fluctuations. The findings have important implications for improving the efficiency and accuracy of scour hole measurements in hydraulic engineering, particularly for submerged wall-jet scouring, and the developed code can also be applied to other optical measurement devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.