Abstract

Detection, localization and evaluation of internal defects are important subjects for the integrity management of aluminum tubes which are widely used in heat exchange, aerospace, transport and construction fields. Conventional nondestructive testing (NDT) methods are difficult to detect, locate and evaluate the internal defect in aluminum tubes in a one-pass scan. This paper presents an inner circumferential current field testing method for the inspection of inner-wall longitudinal cracks in aluminum tubes. The theory of the inner circumferential current field testing method is proposed, which is verified by simulations and experiments. The inner circumferential current field testing system is developed with tunnel magneto resistance (TMR) sensor arrays and the inner-wall longitudinal crack detection experiments are carried out in an aluminum tube. The results show that the inner-wall longitudinal crack can be detected, positioned and evaluated inside the aluminum tube in a one-pass scan using the circumferential current field testing system with TMR sensor arrays.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.