Abstract
Capacitive micromachined ultrasonic transducers (CMUTs) with a perforated membrane have been fabricated and characterized in air. Two types of CMUT device have been fabricated having perforation ratio (area ratio of holes = AR) of 10% and 20%, and analyzed about electrical and mechanical characteristics. The perforation ratio (AR) of membrane substantially influences on the electrostatic force and mechanical restoring force of the device since it leads to the area variation of electrode and membrane, it subsequently influences on the sensitivity and frequency response of the CMUT device. The electrostatic force and mechanical restoring force were improved by decreasing the AR and increasing the DC bias voltage. The open-circuit sensitivity of a CMUT having AR 10% membrane, 8.45 μV/Pa, is larger than that of AR 20%, 4.07 μV/Pa at DC 15 V. Furthermore, the resonance behaviors were observed in the range of 60–80 kHz, and the resonance frequency could be changed by varying the applied DC voltage and AR.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.