A review is presented of the method of images as used in situations in which there is an absolute hydrologic barrier, and possible sources for misinterpretation of pump test results are stressed. The method is then applied to the case of non-equilibrium flow in the presence of a partial hydrologic barrier, under certain limitations. It concluded that the presence of such a barrier may not be reflected in any discernible way in drawdown–time curves resulting from pump tests, or, if it is reflected, may easily be overlooked.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.