Abstract

INTRODUCTION: Dental bleaching is a conservative method for the aesthetic restoration of stained teeth. However, whitening treatments are likely to cause adverse effects when not well planned and executed. OBJECTIVE: This study evaluated the influence of whitening gel on temperature rise in the pulp chamber, using the in-office photoactivated dental bleaching technique. MATERIAL AND METHOD: The root portion of an upper central human incisor was sectioned 3mm below the cemento-enamel junction. The root canal was enlarged to permit the insertion of the K-type thermocouple sensor (MT-401) into the pulp chamber, which was filled with thermal paste to facilitate the transfer of heat during bleaching. Three photosensitive whitening agents (35% hydrogen peroxide) were used: Whiteness HP (FGM), Whiteness HP Maxx (FGM) and Lase Peroxide Sensy (DMC). An LED photocuring light (Flash Lite - Discus Dental) was used to activate the whitening gels. Six bleaching cycles were performed on each group tested. The results were submitted to one-way ANOVA and LSD t-test (α<0.05). RESULT: The lowest mean temperature variation (ºC) was detected for Lase Peroxide Sensy (0.20), while the highest was recorded for Whiteness HP (1.50). CONCLUSION: The Whiteness HP and Whiteness HP Maxx whitening gels significantly affected the temperature rise in the pulp chamber during bleaching, and this variation was dependent on the type of whitening gel used.

Highlights

  • Dental bleaching is a conservative method for the aesthetic restoration of stained teeth

  • The idea of potentiated bleaching dates from 1918, when Abbot reported the use of a high-intensity light source to increase the temperature of the hydrogen peroxide

  • Regard the frequent introduction of new techniques, materials and equipment designed for dental bleaching, and the wide popularity of photoactivated whitening therapies, the objective of the present study is to evaluate the influence of whitening gels, activated with a light source, on the change in pulp chamber temperature

Read more

Summary

Introduction

Dental bleaching is a conservative method for the aesthetic restoration of stained teeth. Objective: This study evaluated the influence of whitening gel on temperature rise in the pulp chamber, using the in-office photoactivated dental bleaching technique. Conclusion: The Whiteness HP and Whiteness HP Maxx whitening gels significantly affected the temperature rise in the pulp chamber during bleaching, and this variation was dependent on the type of whitening gel used. Light or laser heat sources are used to increase the temperature of the whitening product on the tooth surface. It is common, currently, to find highly detailed reports of so-called photoactivated (photopotentiated) whitening treatments where additional light is used together with the whitening agent[5]

Objectives
Methods
Findings
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call