Abstract

The results of an experimental investigation of staggered tube bundle heat transfer to upward and downward moving vertical foam flow are presented in this article. It was determined that a dependency exists between tube bundle heat transfer intensity on foam volumetric void fraction, foam flow velocity and direction, and liquid drainage from foam. In addition to this, the influence of tube position of the bundle on heat transfer was investigated. Experimental results were summarized by criterion equations, which can be applied in the design of foam type heat exchangers.