Abstract

To evaluate the influence of pH variation on the solubility and water sorption of a premixed calcium silicate-based root canal sealer (EndoSequence BC Sealer) compared to the gold standard based on epoxy resin (AH Plus Jet) after immersion in distilled water and phosphate-buffered saline (PBS). Solubility and water sorption were evaluated after immersion in distilled water or PBS at several pHs (5, 7 and 12) and the values were calculated as percentages of the original mass after 24h, 7 and 30days of immersion. The crystalline structures present in the sealers and surface precipitates were assessed by X-ray diffraction. The Shapiro-Wilk's test revealed that data were normally distributed; thus, statistical analysis was performed using one-way anova and Tukey's tests or independent t-test, assuming a 5% α-error. EndoSequence BC Sealer was associated with significantly greater water sorption and solubility compared to AH Plus Jet in all tested conditions (P<0.05). The acid environment increased the 24h solubility of EndoSequence BC Sealer immersed in PBS (P<0.05) and did not induce significative changes in the water sorption (P>0.05). Alkaline pH reduced the solubility of EndoSequence BC Sealer and increased that of AH Plus Jet at all experimental times and soaking media (P<0.05). Alkaline environment also significantly increased the water sorption of AH Plus Jet immersed in PBS (P<0.05). Immersion in PBS significantly reduced the solubility of EndoSequence BC Sealer and significantly increased that of AH Plus Jet (P<0.05). Precipitates on the surface of EndoSequence BC Sealer corresponding to hydroxyapatite and calcium carbonate were detected after immersion in PBS at pH 5 and 7 for 30days. EndoSequence BC Sealer had significantly greater solubility and water sorption than AH Plus Jet. Although the alkaline pH and soaking media directly influenced the solubility and water sorption of the sealers, the solubility of AH Plus Jet remained within the limits recommended by ISO 6876, whilst the solubility of the EndoSequence BC Sealer did not comply with ISO recommendations in all the conditions tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.