Abstract

The influence of a combustor located just upstream of a nozzle guide vane cascade on the heat flux distribution to the nozzle guide vane was experimentally investigated. The surface temperature distribution around the convectively cooled vane of the cascade was obtained by locating the cascade, firstly in a low-turbulence uniform hot gas stream, secondly in a high-turbulence, uniform hot gas stream, and thirdly in a high-turbulence, nonuniform hot gas stream present just downstream of the combustor exit. The results indicate that the increased blade surface temperatures observed for the cascade placed just downstream of the combustor can be accounted for by the prevailing turbulence level measured at cascade inlet in cold-flow conditions and the average gas temperature at the cascade inlet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.