Abstract

The paper presented the analysis of heat consumption for heating in multi-family residential buildings before and after thermal retrofitting. The analysis involved four groups of buildings, i.e., 43 buildings in total, located in various localities, belonging to one weather station. The predicted level of energy savings resulting from thermal retrofitting was achieved from the energy audits. The actual heat consumption, following the calculation into so-called external standard conditions, was obtained based on the readouts from heat-meters. For each building, the values of heat consumption over the periods of 6–10 years were read. The performance measurements involved the periods before, during, and after thermal retrofitting. The following statistical tests were used for data analysis: Wilcoxon–Mann–Whitney, Shapiro–Wilk, Bartlett, ANOVA, Kruskal–Wallis, Dunn and Holm post-hoc. The performed analyses showed that the mean value of energy savings predicted by audits reached 38.5% when the real mean value of savings, achieved from heat-meters, equaled 30.3%. The annual energy demand factors for heating were calculated for final energy and non-renewable primary energy factors. It was established that most of the analyzed objects fulfilled the primary energy factor requirements found in the Polish technical and construction regulations, which were valid at the time of investment.

Highlights

  • For several decades, numerous countries around the world, Poland included, have striven to improve the energy efficiency in various branches of the economy [1,2]

  • The following paper focuses on energy consumption for heating in multi-family buildings before and after comprehensive thermal retrofitting

  • The values of average corrected heat consumption before and after thermal retrofitting were presented and the percentage gains resulting from thermal retrofitting were defined

Read more

Summary

Introduction

Numerous countries around the world, Poland included, have striven to improve the energy efficiency in various branches of the economy [1,2]. Comprehensive actions aimed at reducing the energy consumption in buildings have been taken in Poland and in other European countries for over 20 years [5,6,7,8,9]. Such actions should not deteriorate the room use conditions. In the case of residential multi-family buildings having no cooling system, the highest energy demand throughout the year is connected with meeting the heating requirements while maintaining thermal comfort in rooms. Stringent requirements related to the thermal insulation of wall

Methods
Results
Discussion
Conclusion