Abstract

The influence of temperature in the range 25 to 80°C on the dissolution of tin was investigated in an acidic solution at pH4 containing 0.1 to 1m NaCl. The corrosion current is slightly dependent on both the temperature and the Cl− ion concentration. The main dissolution characteristics of tin are $$\left( {\frac{{\partial E}}{{\partial \log i}}} \right)_{{\text{Cl}}^ - } \approx \frac{2}{3}\frac{{RT}}{F}\left( {\frac{{\partial \log i}}{{\partial \log a_{{\text{Cl}}^ - } }}} \right) \approx i$$ with an apparent energy of activation of 33 kJ mol−1 as long as the electrode surface is bare, whence it is deduced that the dissolution process is the same over the entire range of temperatures and concentrations under consideration. The behaviour of tin is different when a precipitate is formed on its surface, which is generally observed atE>−0.5V sce. The changes occurring on the electrode surface were observed by semi-quantitative energy dispersive X-ray analysis and scanning electron microscopy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.