Abstract

In this paper we investigated whether a different accuracy in sample cleaning prior to the analysis may affect the elemental composition of unwashed samples of the lichen Xanthoria parietina. To this purpose, samples of this lichen were collected from a remote area of Sardinia (Italy) and randomly divided into two aliquots, one cleaned very carefully (ca. 3-4 h to obtain ca. 200 mg of material for analysis) and the other cleaned with a lower efficiency (ca. 1-2 h). Samples were analysed by ICP-MS for the content of Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, V and Zn. The results indicated that an accurate cleaning is effective for reducing the content of Al and Fe, i.e. soil-related elements, but that it has no effect on the concentrations of other elements less represented in the soil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.