Abstract

In order to improve the HXR emission from APF plasma focus device we have investigated the effect of insulator sleeve outer diameter (O.D.) and its length. Fourteen different insulator sleeve geometries at three different filling gas pressures of 6, 7 and 8 Torr of neon are used in the present investigation. The average HXR yield, measured using scintillation detector, has been found to increase with the increase in insulator sleeve O.D. from 31 to 34 mm. Further increase in insulator sleeve diameter to 37 mm, however, decreased the HXR yield. The highest magnitude of 234.5 kA was achieved for 34 mm O.D. of sleeve at filling gas pressure of 7 Torr and voltage of 12 kV.