Abstract. Experiments using an SVC spectroradiometer ranging from 0.35 to 2.5 µm are being conducted in the field as part of the current research in order to gain a better understanding of how contamination affects spectral characteristics. Utilizing a spectroradiometer (0.35–2.5 µm), studies were carried out in the field to determine the linear mixing of snow pollutants (such as coal, ash, wood, and soil) with snow in terms of concentration of contaminants in order to simulate and comprehend the spectrum response of real-world scenarios. Present studies contribute to mapping snow and contaminated snow pixels in remote sensing RS data based on of linear mixing, and to identifying and discriminating between different types of snow contaminants in respect of linear mixing manner, via appropriate wavelength selections for future studies.