Abstract

Carbon fiber reinforced polymer, CFRP, composite materials have been used to fabricate space mirror. Usually the composite space mirror can completely replicate the high-precision surface of mould by replication process, but the actual surface accuracy of replicated space mirror is always reduced, still needed further study. We emphatically studied the error caused by layup and curing on the surface accuracy of space mirror through comparative experiments and analyses, the layup and curing influence factors include curing temperature, cooling rate of curing, method of prepreg lay-up, and area weight of fiber. Focusing on the four factors, we analyzed the error influence rule and put forward corresponding control measures to improve the surface figure of space mirror. For comparative analysis, six CFRP composite mirrors were fabricated and surface profile of mirrors were measured. Four guiding control measures were described here. Curing process of composite space mirror is our next focus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.