Abstract

This paper reports on part of an ongoing experimental program at The University of Adelaide on FRP-concrete-steel composite columns. A total of eight high-strength concrete double-skin tubular columns (DSTCs) were tested under axial compression. The column parameters examined included the diameter, thickness, and shape of inner steel tube. The results of the experimental study show that increasing the inner steel tube diameter leads to an increase in the ultimate axial stress and strain of concrete in DSTCs. The results also show that increasing inner steel tube thickness leads to an increase in the ultimate axial stress and strain of DSTCs. Furthermore, it is observed that concrete inside DSTCs with square inner steel tubes is not confined as effectively as concrete inside DSTCs with circular inner steel tubes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call