Abstract

BackgroundEpidemiological studies have reported associations between air pollution and neuro-psychological conditions. Biological mechanisms behind these findings are still not clear. ObjectivesWe examined changes in blood and urinary neural biomarkers following exposure to concentrated ambient coarse, fine and ultrafine particles. MethodsFifty healthy non-smoking volunteers, mean age 28years, were exposed to coarse (2.5–10μm, mean 213μg/m3) and fine (0.15–2.5μm, mean 238μg/m3) concentrated ambient particles (CAPs), and filtered ambient and/or medical air. Twenty-five participants were exposed to ultrafine CAP (mean size 59.6nm, range 47.0–69.8nm), mean (136μg/m3) and filtered medical air. Exposures lasted 130min, separated by ≥2weeks, and the biological constituents endotoxin and β-1,3-d-glucan of each particle size fraction were measured. Blood and urine samples were collected pre-exposure, and 1-hour and 21-hour post-exposure to determine neural biomarker levels. Mixed-model regressions assessed associations between exposures and changes in biomarker levels. ResultsResults were expressed as percent change from daily pre-exposure biomarker levels. Exposure to coarse CAP was significantly associated with increased urinary levels of the stress-related biomarkers vanillylmandelic acid (VMA) and cortisol when compared with exposure to filtered medical air [20% (95% confidence interval: 1.0%, 38%) and 64% (0.2%, 127%), respectively] 21hours post-exposure. However exposure to coarse CAP was significantly associated with decreases in blood cortisol [−26.0% (−42.4%, −9.6%) and −22.4% (−43.7%, −1.1%) at 1h and 21h post-exposure, respectively]. Biological molecules present in coarse CAP were significantly associated with blood biomarkers indicative of blood brain barrier integrity. Endotoxin content was significantly associated with increased blood ubiquitin C-terminal hydrolase L1 [UCHL1, 11% (5.3%, 16%) per ln(ng/m3+1)] 1-hour post-exposure, while β-1,3-d-glucan was significantly associated with increased blood S100B [6.3% (3.2%, 9.4%) per ln(ng/m3+1)], as well as UCHL1 [3.1% (0.4%, 5.9%) per ln(ng/m3+1)], one-hour post-exposure. Fine CAP was marginally associated with increased blood UCHL1 when compared with exposure to filtered medical air [17.7% (−1.7%, 37.2%), p=0.07] 21hours post-exposure. Ultrafine CAP was not significantly associated with changes in any blood and urinary neural biomarkers examined. ConclusionAmbient coarse particulate matter and its biological constituents may influence neural biomarker levels that reflect perturbations of blood-brain barrier integrity and systemic stress response.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call