Abstract
Background: Dental implants have provided an alternative method of prosthetic rehabilitation with high long-term success rates. However, mechanical or biological complications may occur with implants amongst which loosening of the screw is very common. Loosening of the screw might cause misfit of implant‒abutment interface and may occur due to preload loss subsequent to inadequate initial torque, distortion of the screw, wear of the screw, overloading, and micro-movements because of functional loading. The implant-abutment connection design like internal hex, external hex and morse taper may affect the screw stability. The effect of various implant-abutment connections on the stability of abutment screw has been discussed in this systematic review.
 Aim: The aim of this review is to assess and compare effect of different abutment connections on loosening of the screw.
 Data Sources: An online search was made for the articles using Google Scholar and PubMed.
 Study Eligibility Criteria: Articles published in English language or those articles that have a detailed summary in English language were included. Articles published between 1st January 2000 and 30th September 2018 were selected. Scientific research papers, Randomized controlled trials were included with data on the effect of various implant abutment connections on the loosening of the screw.
 Results: Out of 449 articles that were identified through electronic database searching. 19 articles were selected. These articles were screened for duplicates and 7 articles were obtained after eliminating the duplicates. None were excluded after screening of the duplicate articles. This review provides an understanding of effect of various abutment connections on loosening of the screw.
 Limitations: Few articles do not give concrete conclusions due to smaller sample sizes, differences inter-study sample population, variety of groups compared.
 Conclusions: Out of all studies that were evaluated few stated that internal hex connection design had least screw loosening compared to external hex and morse taper while the other studies were inconclusive.
 Keywords: Dental Implant, Implant-Abutment Connection, Screw Loosening
Highlights
The screw is a crucial part of implant prosthesis
Out of 7 studies, three studies stated that internal hex connection design had least screw loosening compared to external hex and morse taper while the other studies were inconclusive (Table 2)
There were no statistical differences in the Removal Torque Value among three groups Internal connection exhibited better torque maintenance compared to the external hexagon connection
Summary
The screw is a crucial part of implant prosthesis. Screw loosening might cause displacement of prosthesis leading to loss of function.[1]. Initial torquing, deformation of screw, wear of the screw, over-loading, and micro-movements due to functional loading.[2] Various designs of implant abutment connection have been put forth to reduce the microgap.[4]. Loosening of the screw might cause misfit of implant‒abutment interface and may occur due to preload loss subsequent to inadequate initial torque, distortion of the screw, wear of the screw, overloading, and micro-movements because of functional loading. The implant-abutment connection design like internal hex, external hex and morse taper may affect the screw stability. Aim: The aim of this review is to assess and compare effect of different abutment connections on loosening of the screw. Conclusions: Out of all studies that were evaluated few stated that internal hex connection design had least screw loosening compared to external hex and morse taper while the other studies were inconclusive.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Medical and Biomedical Studies
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.