Sensitization and intergranular stress corrosion cracking (IGSCC) behavior of deformed AISI 304 prior to aging at temperature 500 °C were investigated. Sensitization was evaluated by double loop electrochemical potentio-kinetic reactivation method and IGSCC studies were carried out using slow strain rate tests in polythionic acid (PTA). The degree of sensitization (DOS) obtained for undeformed specimens was very low as compared to that of deformed prior to sensitization. The undeformed, sensitized AISI 304 was resistant to IGSCC in PTA solution. The specimens deformed by 20 and 40% reduction in thickness were undergone IGSCC (brittle cracking). The deformation >40% prevented the IGSCC, even though the % DOS was significantly high.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.