Abstract

Exposure to ultrafine particles has a significant influence on human health. In regions with large commercial airports, air traffic and ground operations can represent a potential particle source. The particle number concentration was measured in a low-traffic residential area about 7 km from Frankfurt Airport with a Condensation Particle Counter in a long-term study. In addition, the particle number size distribution was determined using a Fast Mobility Particle Sizer.The particle number concentrations showed high variations over the entire measuring period and even within a single day. A maximum 24 h-mean of 24,120 cm−3 was detected. Very high particle number concentrations were in particular measured when the wind came from the direction of the airport. In this case, the particle number size distribution showed a maximum in the particle size range between 5 and 15 nm. Particles produced by combustion in jet engines typically have this size range and a high potential to be deposited in the alveoli. During a period with high air traffic volume, significantly higher particle number concentrations could be measured than during a period with low air traffic volume, as in the COVID-19 pandemic.A large commercial airport thus has the potential to lead to a high particle number concentration even in a distant residential area. Due to the high particle number concentrations, the critical particle size, and strong concentration fluctuations, long-term measurements are essential for a realistic exposure analysis.