Abstract

The CS Insert Coil (CSIC), a well-instrumented 140 m long Nb3Sn solenoid wound one-in-hand and installed in the bore of the CS Model Coil, was tested during the summer of 2000 at JAERI Naka, Japan, within the framework of the International Thermonuclear Experimental Reactor large projects [1]. The maximum transport current in the CSIC was 40 kA and the peak background field was 13 T. The coils were cooled by forced flow HeI nominally at 4.5 K and 0.6 MPa. An inductive heater was used to test stability and quench of the CSIC. In this second of two companion papers we concentrate on the analysis of quench initiation and propagation, based on the study of heater calibration and conductor stability presented in the first paper [2]. The initiation and propagation of an inductively driven quench was tested here for the first time in a two-channel Nb3Sn conductor, for different transport currents, delay times of the dump, and temperature margins, and a selection of the corresponding results will be presented and...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.