Abstract

The paper presents a proposed system that supplies a 400 Hz single-phase onboard grid from the DC onboard bus. This system enables independent compensation of reactive power in the AC grid. Independent control of active and reactive power flow requires the decomposition of current in the grid into active and reactive components. Independent control of active and reactive power requires the use of synchronizers that operate in the dq frame system. If synchronization is performed with a single-phase grid, the transformation of dq requires the virtual quadrature signals. Standard quadrature signal generation systems use a second-order generalized integrator. To improve the dynamics of the system, the paper proposes a new quadrature generator that operates on the basis of trigonometric calculations instead of a second-order integration system. The developed system was implemented in a proportional-resonant current control system. Tests carried out in steady state and in dynamic states related to typical grid disturbances proved significantly better dynamic properties than those of a standard integrator-based system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.