Abstract

This study presents an exergetic comparison when feedwater-heating repowering method is used in a coal fired thermal power plant. Design data for Soma-A Thermal Power Plant was used to calculate the exergetic efficiency before repowering. Secondly, the exergetic efficiency calculations were repeated for thermal power plant after feedwater-heating repowering method. It was found that exergy destruction (ED) in combustion chamber (boiler) decreased from 84% to 66%. However, exergy destruction for the combustion chamber of gas turbine (GT) was found to be 15%. Total exergy destruction increased from 54.4 MW to 69 MW. However, total exergy destruction per installed capacity decreased from 2.3 MW/MWel to 1.99 MW/MWel. In addition, exergetic efficiencies for the designed and repowered cycles were found to be 31% and 34%, respectively. In conclusion, the feedwater-heating repowering method can increase the exergetic efficiency of the coal fired thermal power plants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.