Abstract

Background. Among patients with chronic disease, percutaneous endoscopic gastrostomy (PEG) tubes are a common mechanism to deliver enteral feedings to patients unable to feed by mouth. While several cases in the literature describe difficulties with and complications of the initial placement of the PEG, few studies have documented the effects of a delayed diagnosis of a misplaced tube. Methods. This case study reviews the hospitalization of an 82 year old male with an inadvertent placement of a PEG tube through the transverse colon. Photos of the placement in the stomach as well as those of the follow up colonoscopy, and a recording of the episodes of diarrhea during the hospitalization were made. Results. The records of this patient reveal complaints of gastrointestinal distress and diarrhea immediately after placement of the tube. Placement in the stomach was verified by endoscopy, with discovery of the tube only after a follow up colonoscopy. The tube remained in place after this discovery, and was removed weeks after the diarrhea was unsuccessfully treated with antibiotics. After tube removal, the patient recovered well and was sent home.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.