Abstract

To obtain quantitative efficacy data of two ultraviolet light (UVC) technologies for surface inactivation of Bacillus anthracis Ames and Bacillus atrophaeus spores. Spores were deposited onto test coupons and controls of four different materials, via liquid suspension or aerosol deposition. The test coupons were then exposed to UVC light from either a low-pressure mercury vapor lamp or a system comprised of light emitting diodes, with a range of dosages. Positive controls were held at ambient conditions and not exposed to UVC light. Following exposure to UVC, spores were recovered from the coupons and efficacy was quantified in terms of log10 reduction (LR) in the number of viable spores compared to that from positive controls. Decontamination efficacy varied by material and UVC dosage (efficacy up to 5·7 LR was demonstrated). There was no statistical difference in efficacy between the two species or between inoculation methods. Efficacy improved for the LED lamp at lower relative humidity, but this effect was not observed with the mercury vapor lamp. This study will be useful in determining whether UVC could be used for the inactivation of B. anthracis spores on different surface types.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.