Abstract
ObjectivesTo investigate the type of failure and fracture resistance behaviour of different zirconia and titanium implant/abutment systems for anterior application. MethodsEight groups of implant–abutment combinations (n=8/system) were restored with identical full-contour zirconia crowns. The systems represented one-piece and multi-piece zirconia (Z) or titanium (T) implants/abutments with different types of connection (screwed=S, bonded=B). The following combinations (implant–abutment-connection) were investigated: ZZS, ZZB, ZZZB (three-piece), ZTS, TTS, TTS reference, and Z (one-piece, 2×). To simulate clinical anterior loading situations the specimens were mounted into the chewing simulator at an angle of 135° and subjected to thermal cycling (2×3000×5°/55°C) and mechanical loading (1.2×106×50N; 1.6Hz). Fracture resistance and maximum bending stress were determined for all specimens that survived ageing. Data were statistically analyzed with the Kolmogorov–Smirnov-test and one-way ANOVA (α=0.05). Survival performance was calculated with the Kaplan–Meier Log-Rank test. ResultsIndependent of the material combinations screwed systems showed partly failures of the screws during simulation (ZZS: 3×, ZTS: 8×, TTS: 3×). Screw failures were combined with implant/abutment fractures of zirconia systems. Zirconia one-piece implants and the reference system did not show any failures, and only one specimen of the systems with a bonded connection (ZZZB) fractured. Mean (±standard deviation) fracture forces and maximum bending stresses differed significantly (p=0.000) between 187.4±42.0N/250.0±56.0N/mm2 (ZZZB) and 524.3±43.1N/753.0±61.0N/mm2 (Z). ConclusionsBoth material (zirconia or titanium) and the type of connection influenced failure resistance during fatigue testing, fracture force, and maximum bending stress. Clinical significanceDifferent material combinations for implants and abutments as well as different types of connection achieved acceptable or even good failure and fracture resistance that may be satisfactory for anterior clinical application.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have