Abstract
BackgroundThe aim of this study was (1) to determine and compare the shear bond strength (SBS) of a bioactive composite “Activa Bioactive Restorative” with and without bonding agent and a nanocomposite “Filtek Z350 XT/Z350” and (2) to measure and compare the amount of fluoride release from a bioactive composite “Activa Bioactive Restorative” and a glass ionomer ”Equia forte”. Material and MethodsForty two dentin surfaces from freshly extracted human molars were prepared for shear bond strength testing. The specimens were randomly divided into three equal groups. The restorative materials were applied to all dentin surfaces according to the manufacturer’s instructions, using a special jig (Ultradent) in the following manner : Group 1 (Activa Bioactive Restorative with adhesive), Group 2 (Activa Bioactive Restorative without adhesive) and Group 3 (Filtek Z350 XT/Z350). The bonded specimens were subjected to thermocycling in 5°C and 55°C water baths then tested for SBS in a universal testing machine (1 mm/minute). Kolmogorov-Smirnov and Levene tests were used to evaluate the distribution of the variable and the equality of variances respectively and a Student’s T- test was applied to compare the mean strength between the groups. In the next test, thirty disc shaped specimens were fabricated using Activa BioActive restorative and Equia Forte; 15 specimens from each material. The specimens of each group were immersed separately in 5 ml of deionized water. Fluoride release was measured daily throughout 15 days using a fluoride-specific ion electrode and an ion-analyzer. Repeated measures analysis of variance with one within-subject factor (time) and one between-subject factor (Activa Bioactive / Equia Forte) was applied to compare the amount of released fluoride between groups and within time. It was followed by univariate analyses and Bonferroni multiple comparisons tests. ResultsThe mean shear bond strength of Activa Bioactive Restorative with adhesive was found to be 17.379 (± 8.5043) MPa and 19.443(± 8.3293) MPa for the Filtek Z350 XT/Z350 group. There was no significant difference between both groups. Regarding fluoride release, the amount of Fluoride released was significantly greater in the Equia Forte group compared to the Activa Bioactive group (-p-value<0.05). The mean amount of Fluoride has significantly decreased over time with Activa Bioactive group (-p-value<0.001); it showed the highest fluoride release during the first 24 hours post-setting. Also in the Equia Forte group, the mean amount of Fluoride release showed a progressive and significant decrease over time (-p-value<0.001), although the amount of Fluoride released was significantly greater in the Equia Forte group compared to the Activa Bioactive group (-p-value<0.05). ConclusionsActiva Bioactive Restorative with adhesive and a nanocomposite showed similar bond strengths. Activa Bioactive Restorative doesn’t have the self-adhesive property. The fluoride ion release profile of Activa was lower than that of the Equia Forte. Key words:Bioactive composite, nanocomposite, glass ionomer, fluoride release, shear bond strength, thermocycling.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.