Abstract

Objective: To characterize the pulse characteristics and risk of fiber fracture (ROF) of the pulsed-Thulium:YAG (p-Tm:YAG) laser and to compare its ablation volumes (AVs) against Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) laser and Thulium fiber laser (TFL). Materials and Methods: p-Tm:YAG (100 W-Thulio, Dornier-Medtech©, Germany) was characterized using single-use 272 μm core-diameter-fibers. p-Tm:YAG characterization included pulse shape, duration, and peak power (PP) studies. ROF was assessed after 5 minutes of continuous laser activation (CLA) at five decreasing fiber bend radii (1, 0.9, 0.75, 0.6, and 0.45 cm). p-Tm:YAG, Ho:YAG (120 W-Cyber-Ho, Quanta®, USA), and TFL (60 W-TFLDrive, Coloplast®, Denmark) AVs were compared using a 20-mm linear CLA at 2 mm/second velocity in contact with 20 mm3 hard stone phantoms (HSP) and soft stone phantoms (SSP) (15:3 and 15:5 water to powder ratio, respectively) fully submerged in saline at 0.5 J-20 Hz or 1 J-10 Hz. After CLA, phantoms underwent three-dimensional (3D) micro-scanning (CT) and subsequent 3D segmentation to estimate the AVs, using 3DSlicer©. Each experiment was performed in triplicate. Results: p-Tm:YAG presents a uniform pulse profile in all of the available preset modes. PP ranged from 564 to 2199 W depending on pulse mode. No laser fiber fracture occurred at any bend radius. p-Tm:YAG achieved similar mean AVs to TFL and Ho:YAG for HSP (8.96 ± 3.1 vs 9.78 ± 1.1 vs 8.8 ± 2.8 mm3, p = 0.67) but TFL was associated with higher AVs compared with p-Tm:YAG and Ho:YAG (12.86 ± 1.85 vs 10.12 ± 1.89 vs 7.56 ± 2.21 mm3, p = 0.002) against SSP. AVs for HSP increased with pulse energy for p-Tm:YAG and Ho:YAG and (11.56 ± 1.8 vs 6.36 ± 0.84 mm3 and 11.27 ± 1.98 vs 6.34 ± 0.55 mm3, p = 0.03 and p = 0.02), whereas AVs for SSP were similar across laser settings for all laser sources. AVs with TFL were similar across laser settings for both phantom types. Conclusion: p-Tm:YAG combines intermediate PP between Ho:YAG and TFL, a uniform pulse profile, no ROF with increasing deflection and effective ablation rates. Further clinical studies are needed to confirm these in vitro results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.