Abstract

Experimental determination of test gas caloric quantities in high-enthalpy ground testing is impeded by excessive pressure and temperature levels as well as minimum test timescales of short-duration facilities. Yet, accurate knowledge of test gas conditions and stagnation enthalpy prior to nozzle expansion is crucial for a valid comparison of experimental data with numerical results. To contribute to a more accurate quantification of nozzle inlet conditions, an experimental study on non-intrusive in situ measurements of the post-reflected shock wave stagnation temperature in a large-scale free-piston reflected shock tunnel is carried out. A series of 20 single-shot temperature measurements by resonant homodyne laser-induced grating spectroscopy (LIGS) is presented for three low-/medium-enthalpy conditions (1.2–2.1 MJ/kg) at stagnation temperatures 1100–1900 K behind the reflected shock wave. Prior limiting factors resulting from impulse facility recoil and restricted optical access to the high-pressure nozzle reservoir are solved, and advancement of the optical set-up is detailed. Measurements in air agree with theoretical calculations to within 1–15%, by trend reflecting greater temperatures than full thermo-chemical equilibrium and lesser temperatures than predicted by ideal gas shock jump relations. For stagnation pressures in the range 9–22 MPa, limited influence due to finite-rate vibrational excitation is conceivable. LIGS is demonstrated to facilitate in situ measurements of stagnation temperature within full-range ground test facilities by superior robustness under high-pressure conditions and to be a useful complement of established optical diagnostics for hypersonic flows.

Highlights

  • Evaluation of experimental test data in high-enthalpy and hypersonic ground testing requires complementary flowfield computations in order to obtain flow quantities of interest that are not available to direct measurement [1]

  • By varying the shock tube (ST) pressure of 0.5 MPa, 0.25 MPa, and 0.15 MPa (C1, C2, and C3), the condition captured for run 1 (C1) is seen to be strongly undertailored, reflecting a post-shock pressure p5(exp) that steadily decreases due to the expansion fan originating from contact surface interaction with the endwall-reflected shock wave

  • Whereas a priori filtering of the raw signal before signal analysis can be advantageous for discrete fast Fourier transform (DFT) frequency analysis, the time-domain nonlinear least-squares curve fitting procedure is found to be very robust against background noise and to be entirely unaffected by signal filtering

Read more

Summary

Introduction

Evaluation of experimental test data in high-enthalpy and hypersonic ground testing requires complementary flowfield computations in order to obtain flow quantities of interest that are not available to direct measurement [1]. For this purpose, the accurate definition of boundary conditions is vital. Total flow enthalpy is determined by quasi one-dimensional (1-D) numerical codes such as L1d, ESTCj [3], or Kasimir [4] based on incident shock Mach number and assuming normal shock relations [5] as well as quasi-steady conditions thereafter, as long as test conditions are properly tailored. The time interval of constant post-shock temperature (and species concentration) can be smaller than quasi-steady pressure duration, i.e., test time, even in tailored interface mode due to premature driver gas

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call