Abstract

The initial discharge process of plasma electrolytic oxidation (PEO) on the 60 vol. % SiCP/2009 aluminum matrix composite in silicate solution was in situ monitored by sound and vibration measurement techniques. The underwater sound, airborne sound, and sample vibration signals were detected in the initial 120s of the PEO process, and their generation mechanism was discussed. In terms of waveforms and spectrograms of the sound and vibration signals, the initial PEO process can be divided into five stages: conventional anodizing stage (I), glow discharge stage (Ⅱ), tiny spark discharge stage (Ⅲ), large spark discharge stage (Ⅳ), and strong spark discharge stage (Ⅴ). The sound and vibration signals during the PEO process are attributed to the evolution of bubbles, which are from the plasma discharge, electrochemical reactions, and vaporization of electrolyte under Joule heat. In stage I, these signals completely come from the bubbles produced by the evaporative electrolyte and electrochemical reactions. In stages Ⅱ-Ⅴ, the bubbles from the plasma discharge gradually become the main source of these signals with increasing discharge intensity. In addition, the spike peaks on the waveforms of these signals at stage Ⅴ are related to the strong discharge sparks. These results demonstrate that sound and vibration measurement techniques can effectively monitor the PEO discharge process.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call