Abstract

New measurement methods and equipment for correct 5G New Radio (NR) electromagnetic field (EMF) in-situ exposure assessment of instantaneous time-averaged exposure (Eavg) and maximum extrapolated field exposure (Emax) are proposed. The different options are investigated with in-situ measurements around 5G NR base stations (FR1) in different countries. The maximum electric field values satisfy the ICNIRP 2020 limit (maximum 7.7%). The difference between Emax and Eavg is <3dB for the different measurement equipment at multiple sites in case there is only self-generated traffic. However, in a more realistic scenario, Eavg cannot be used to assess the exposure correctly due to influence of other users as the spatial distribution of user equipment (UE) influences Eavg, while Emax is not affected. However, when multiple UEs are collocated, there is no influence of the number of UEs. A broadband measurement can give a first impression of the RF-EMF exposure up to 700m, but is not enough to assess the 5G-NR exposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.