Abstract

Correct staging and treatment initiation in malignant lymphoma depends on accurate lymph node characterization. However, nodal assessment based on conventional and diffusion-weighted (DWI) MRI remains challenging, particularly in smaller nodes. To evaluate first-order apparent diffusion coefficient (ADC) texture parameters compared to mean ADC for lymph node characterization in non-Hodgkin lymphoma (NHL) using whole-body DWI (WB-DWI). Retrospective. Twenty-eight patients with NHL. 3T whole-body DWI using two b-values (0-1000 s/mm2 ). Regions of interest were drawn on the three most hyperintense lymph nodes on b1000-images, irrespective of size, in all nodal body regions. Diagnostic performance of mean ADC (ADCmean ) was compared with first-order ADC texture parameters: standard deviation (ADCstdev ), kurtosis (ADCkurt ), and skewness (ADCskew ). Additional subanalyses focused on the accuracy of ADCmean and ADC texture parameters in different lymph node volumes and nodal regions. Benign and malignant nodes were compared using Mann-Whitney U-tests with 18-Fluoro-deoxyglucose positron emission tomography computed tomography and bone marrow biopsy as reference standard. Receiver operating characteristic analyses were performed to determine cutoff values and calculate sensitivity, specificity, accuracy, and positive and negative predictive value (PPV, NPV). ADCmean (P = 0.008), ADCskew and ADCkurt differed significantly between benign and malignant nodes (P < 0.001), while ADCstdev didn't (P = 0.21). ADCskew was the best discriminating parameter, with 79% sensitivity, 86% specificity, 83% accuracy, 85% PPV, and 81% NPV. In every volume category, ADCskew yielded the highest accuracy (88% in 0-25th percentile volume, 75% in 25th -75th percentile, 93% in 75-100th percentile). On a per-region basis, ADCskew accuracy varied 13.6% between nodal regions, while ADCmean , ADCkurt , and ADCstdev showed interregional variation of 17.4%, 20.3%, and 14.9%, respectively. First-order ADC texture analysis with WB-DWI improved lymph node characterization compared to ADCmean . ADCskew was the most accurate and robust discriminatory parameter over all lymph node volumes and nodal body regions. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:897-906.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.