Polystyrene (PS) thin film with various concentration of mass (1%, 3%, and 5%) has been deposited onto Quartz Crystal Microbalance (QCM) surface by a spin coating method. The purpose of this research is the improvement of Bovine Serum Albumin (BSA) immobilization into the QCM surface. The QCM resonance frequency has been investigated by means of Impedance Analyzer. The film thickness was calculated by the Sauerbrey equation. The surface roughness of the PS layer was observed by noncontact Topography Measuring System (TMS-1200). Calculation result using a Sauerbrey equation shows the thickness of the PS layer increases with the increasing PS concentration. The QCM/PS with 1% and 5% concentration of mass has rougher morphology and more frequency shifts caused by BSA injection compared to 3% concentration of PS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.