Abstract

Introduction. Increasing demands of precise geometry measurements by science and industry cause the necessity of improvement in an associated branch of legal and practical metrology. One of the most significant fields is the measurement of internal dimensions and so the issues with the unit of meter transfer. Now we face the situation when the current accuracies of National standards of different levels in corresponding traceability chain (reference rings measurements) get close to each other. This means that we have to make the standard of upper level more precise. One of the obvious ways is to apply the latest ultra-stable laser locked to a frequency comb.Objective. The objective is to propose possibilities for improvement of the National secondary standard of the unit of length by researching its measuring capabilities to minimize measurement uncertainty.Materials and methods. The calculation of expanded uncertainty of internal diameter measurements by the National secondary standard of the unit of length is performed according to the international document «Guide to the Expression of Uncertainty in Measurement» JCGM 100:2008 approved by BIPM. The secondary standard research results represented in previous reports and publications are also taken into consideration.Results. Detailed uncertainty budget for the proposed measuring system is given as well as graphical data representing the accuracy improvement.Conclusion. Actions for minimization of measurement uncertainty components of the National secondary standard of the unit of length in the field of reference ring internal diameter measurements in combination with state-of-the-art laser interferometer system improve it to the next frontiers of accuracy and precision.

Highlights

  • Increasing demands of precise geometry measurements by science and industry cause the necessity of improvement in an associated branch of legal and practical metrology

  • It’s necessary to mention that according to the new revision of the traceability chain the unit of length – meter has to be transferred from the reference standard to the secondary standard, to internal diameter gauges of the first echelon and down the chain

  • The internal diameter of the reference ring can be evaluated as the function of interferometer readout, laser wavelength, temperature effects including the thermal expansion of ring material, corrections based on optical probe performance and correction on the instrumental error of interferometer system

Read more

Summary

Introduction

Increasing demands of precise geometry measurements by science and industry cause the necessity of improvement in an associated branch of legal and practical metrology. It’s necessary to mention that according to the new revision of the traceability chain the unit of length – meter has to be transferred from the reference standard to the secondary standard, to internal diameter gauges (rings) of the first echelon and down the chain.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.