Abstract

A normalized efficiency function has been calculated (which includes the optimum upper limit of the fitting region, fitting order and γ gate setting) in order to determine the type B uncertainty introduced by extrapolating. The calculated results were applied in the efficiency extrapolation method. The type B uncertainty resulting from extrapolation can be eliminated including the components introduced by different γ gate settings and/or different fitting orders. This method has been applied to the efficiency trace technique, and the results are presented for 147Nd and 35S. The final uncertainties at the 99.7 confidence level were 0.1% and 0.5%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.