Abstract
Fault detection plays an important role in providing reliable operation for permanent-magnet synchronous machine (PMSM). The inter-turn fault is one of the most common faults for the PMSM. Hence, this study focuses on the incipient stage inter-turn fault detection. An improved zero-sequence voltage component-based (ZSVC) inter-turn fault detection method is proposed. In the proposed method, discrete wavelet transform is first applied to remove the noise and harmonic components in the ZSVC for highlighting the fault characteristic component. Then, fast Fourier transform is used to analyse the obtained signal for the inter-turn fault detection. In addition, to show the performance of the proposed method, the commonly used fault detection based on stator current is studied. The effectiveness of the proposed fault diagnosis method is validated by the simulation and experimental results, showing that the proposed method has good performance for the incipient stage inter-turn fault diagnosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.