Abstract

A new hysteresis band current controller for voltage source inverters (VSI) is presented. The current trajectories of the of the three phase system are transformed into the static frame /spl alpha/-/spl beta/, which enables a decoupling of the current error components and facilities the application of the different shapes for the current error boundaries. This new technique, which has been experimentally verified, is based on the use of a second input current error derivative for the selection of the zero voltage vectors V(0, 7), which greatly reduces the inverter switching frequency. Computer simulations and laboratory test were made in order to investigate the performance of the regulator, and results show the effectiveness of the proposed control scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.