Abstract

RF MEMS switches have moving microstructures which are realized either by dry release method or by wet releasing process. In dry release process, suspended bridges gets curled up due to high process temperature while in wet release method, surface of the released devices is get contaminated which affects the final performance of the device. In this paper, a mixed release process of wet and dry is presented to release the stiction free suspended microstructures. Contamination from the devices is removed by plasma cleaning. Isolation of the device under test has been improved to 22 from 15 dB after plasma exposure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.