Abstract
A blue phosphorescent organic light emitting device fabricated under the ultra high vacuum (UHV) condition of 6.5 × 10−7 Pa decreases the initial luminance drop upon lifetesting under a constant dc current of 15 mA/cm2 by 3 times compared to a device fabricated under a high vacuum (HV) condition of 7.6 × 10−6 Pa resulting in a 23% increase in half lifetime. We calculate a water content of 10−4 mol. % in the UHV device emissive layer (EML) and 10−2 mol. % in the HV device EML. We discuss the effects of water on luminance loss and voltage rise for the devices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.