Abstract

A blue phosphorescent organic light emitting device fabricated under the ultra high vacuum (UHV) condition of 6.5 × 10−7 Pa decreases the initial luminance drop upon lifetesting under a constant dc current of 15 mA/cm2 by 3 times compared to a device fabricated under a high vacuum (HV) condition of 7.6 × 10−6 Pa resulting in a 23% increase in half lifetime. We calculate a water content of 10−4 mol. % in the UHV device emissive layer (EML) and 10−2 mol. % in the HV device EML. We discuss the effects of water on luminance loss and voltage rise for the devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.