Abstract
The control force, feedback gain, and actuator stroke of several active vibration isolation systems were analyzed based on a single-layer active vibration isolation system. The analysis shows that the feedback gain and actuator stroke cannot be selected independently and the active isolation system design must make a compromise between the feedback gain and actuator stroke. The performance of active isolation systems can be improved by the joint vibration reduction using an active vibration isolation system with an adaptive dynamic vibration absorber. The results show that the joint vibration reduction method can successfully avoid the compromise between the feedback gain and actuator stroke. The control force and the object vibration amplitude are also greatly reduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.