Abstract
Abstract Safe cathodic protection (CP) limits for prestressing steel in concrete and the adequacy of CP using established criteria were evaluated in regard to hydrogen embrittlement (HE). Impressed-current CP was applied to laboratory scale pilings at current densities from 0.1 μA/cm2 to 3.0 μA/cm2 via a skirt anode located at the waterline. Adequate CP was achieved at positions 25 cm (9.8 in.) above to 50 cm (19.7 in.) below the waterline, according to the 100-mV depolarization criterion, at an apparent applied current density of 0.33 μA/cm2. However, the −780 mVSCE criterion was not met for currents as high as 1.33 μA/cm2 for these positions. Hydrogen production, absorption, and permeation in steel first was observed via embedded hydrogen sensors 50 cm and 25 cm above the water line at an applied current density of 0.33 μA/cm2. Observation of hydrogen production verified concerns that the local oxygen concentration might be depleted readily at modest CP levels and that local pH levels may be below 12.5....